Vue de la page 93
COMe-cSP2 / BIOS Operation
89
Module Hardware Health Configuration
Feature
Option
Description
Module H/W Health Function
Enabled
Disabled
Enables Hardware Health Monitoring Device on module
CPU FAN Ticks Per Revolution
1
2
4
8
Set ‗Ticks per rev‘ according to number of impulses sent by
this type of fan during one full revolution
CPU Fan Divisor
1
2
4
8
16
32
64
128
Adjust Fan Divisor to allow for best display when the
rotation is at the edges of the range. If the value gets out of
range the fan would be displayed non-working although still
running.
Divisor 1: 8800 rpm
Divisor 2: 4400 rpm
Divisor 4: 2200 rpm
Divisor 8: 1100 rpm
Divisor 16: 550 rpm
Divisor 32: 275 rpm
Divisor 64: 137 rpm
Divisor 128: 68 rpm
CPU Fan Control Mode
Manual Mode
Thermal Mode
SMARTFAN TM II
Specify different modes to control the fan
CPU Fan Output Level
15
PWM/DC Output Level
0: fan output is always logical low or at min voltage
15: fan output is always logical high or at max voltage
xx: fan output logic output level is (xx/16*100%)
Target Temperature
045
Temperature value where the fan starts to work
Min = 0, Max = 127
Tolerance Value
01
Tolerance Value