VMP1 NetBootLoader
ID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 13
5.7 Commands
The following commands are available with the NetBootLoader. Where an ellipsis (…) appears
in the command syntax it means that the command is continued from the previous line. Ob-
serve any spaces that may be between the ellipsis and the remainder of the command.
ABORT
FUNCTION: Terminate the NetBootLoader boot operation
SYNTAX:
abort
DESCRIPTION: This command is used by the operator to to terminate the boot
operation during the boot wait time to allow the operator to perform
other NetBootLoader operations. To be asserted it must be issued
during the boot wait time which is indicated by the flashing green
user LED (U) on the CPU board front panel.
BW
FUNCTION: Set or display the parameters of the boot wait function of the
NetBootLoader
SYNTAX:
bw [<time>| -f]
where:
bw command
<time> parameter: value: seconds
1, 2, 5, 10, 20, 50
-f option:
force CRC update
DESCRIPTION: The command “bw” displays the parameter “<time>” setting.
The parameter “<time>” stipulates the waiting time in seconds that
the boot operation is delayed before the application is loaded and
started. No values other than these are supported.
Bear in mind when setting the boot wait time that the green user LED
(U) flashes at the rate of two times a second. Therefore, if the boot
wait is set to 1 second the LED will only flash two times.