48 AT8050
www.kontron.com
Table 4-16:HPM Commands
4.3.2 Sensor Data Records
Information that describes the IPMC capabilities is provided through two mechanisms: capabilities
commands and Sensor Data Records (SDRs). Capabilities commands are commands within the IPMI command
set that return fields providing information on other commands and functions the controller can handle.
Sensor Data Records are data records containing information about the type and number of sensors in the
platform, sensor threshold support, event generation capabilities, and information on what types of
readings the sensor provides. The primary purpose of Sensor Data Records is to describe the sensor
configuration of the hardware management subsystem to system software.
The IPMC are required to maintain Device Sensor Data Records for the sensors and objects they manage.
Access methods for the Device SDR entries are described in the [IPMI 2.0] specification, Section 35, "Sensor
Device Commands."
After a FRU is inserted, the System Manager, using the Shelf Manager, may gather the various SDRs from the
FRU's IPM Controller to learn the various objects and how to use them. The System Manager uses the "Sensor
Device Commands" to gather this information. Thus, commands, such as "Get Device SDR Info" and "Get
Device SDR," which are optional in the IPMI specification, are mandatory in AdvancedTCA systems.
Most of the current Shelf Manager implementation gathers the individual Device Sensor Data Records of each
FRU into a centralized SDR Repository. This SDR Repository may exist in either the Shelf Manager or System
Manager. If the Shelf Manager implements the SDR Repository on-board, it shall also respond to "SDR
Repository" commands.
This duplication of SDR repository commands creates sometime some confusion among AdvancedTCA users.
This is mandatory for IPMC to support the Sensor Device Commands for IPMC built-in SDR as described in the
[IPMI 2.0] specification, Section 35, "Sensor Device Commands." For the ShMC, the same set of commands
for the centralized SDR Repository must be supported but they are described in the [IPMI 2.0] specification,
Section 33, "SDR Repository Commands."
IPMI Spec. section NetFn CMD IPMI BMC req. Carrier IPMC
req.
Kontron support on
IPMC
HPM
Get Target Upgrade
Capabilities
Yes
Get Component
Properties
Yes
Abort Firmware Upgrade Yes
Initiate Upgrade Action Yes
Upload Firmware Block Yes
Finish Firmware Upload Yes
Get Upgrade Status Yes
Activate Firmware Yes
Query Self-Test Results Yes
Query Rollback Status Yes
Initiate Manual Rollback Yes
Vue de la page 63