Kontron ETX-DC Manuel d'utilisateur Page 68

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 81
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 67
ETX-DC®/ BIOS Operation
63
Remote Access Configuration Menu
Feature
Option
Description
Remote Access
Enabled
Disabled
Disables and Enables the AMI Remote
Access feature. It has no influence in
JRC connection.
Serial port number
COM1
COM2
Only enabled COMports while bootup are
supported
Serial Port Mode
115200 8,n,1
57600 8,n,1
38400 8,n,1
19200 8,n,1
09600 8,n,1
Selects the speed of the connection
Flow Control
None
Hardware
Software
Selects the flow control mode
Redirection After BIOS Post
Disabled
Boot Loader
Always
Turns off redirection after POST
Active during POST and boot loader
It is always active
Terminal Type
ANSI
VT100
VT-UTF8
Selects the target terminal type
VT-UTF8 Combo Key Support
Enabled
Disabled
Enable/Disable VT-UTF8 Combination
Key Support for ANSI/VT100 terminals
Sredir Memory Display Delay
No Delay
Delay 1 Sec
Delay 2 Sec
Delay 4 Sec
Selects the delay to display memory
information
Terminal Size
80x24
80x25
Selects terminal size type
Vue de la page 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 80 81

Commentaires sur ces manuels

Pas de commentaire