Kontron COMe Starterkit Eval T2 Manuel d'utilisateur Page 158

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 218
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 157
Power and Reset
3.2.3. ATX and AT Power Sequencing Diagrams
A sequence diagram for an ATX style boot from a soft-off state (S5), initiated by a power button
press, is shown in Figure 64 below.
A sequence diagram for an AT style boot from the mechanical off state (G3) is shown in Figure
65 below below.
In both cases, the VCC_12V, VCC_5V and VCC_3V3 power lines should rise together in a
monotonic ramp with a positive slope only, and their rise time should be limited. Please refer to
the ATX specification for more details.
PICMG
®
COM Express
®
Carrier Board Design Guide Rev. 2.0 / December 6, 2013
158/218