3.4 Electrical Specification
Supply Voltage
» ATX Main Power 24pin
» ATX_12V P4 connector (wide range input depends on module specification)
Power Supply Rise time
» The input voltages shall rise from ≤10% of nominal to within the
regulation ranges within 0.1ms to 20ms.
» There must be a smooth and continuous ramp of each DC input voltage
from 10% to 90% of its final set-point following the ATX specification
Supply Voltage Ripple
» Maximum 100 mV peak to peak 0-20MHz