Kontron AM5020 IPMI Firmware Manuel d'utilisateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
IPMI Firmware AM5020
Page 24 ID 1045-0205, Rev. 1.0
P R E L I M I N A R Y
4.3 OEM Event/Reading Types
Kontron’s OEM specific sensor types and sensor event type codes are presented in the follow-
ing table.
Table 14: OEM Event/Reading Types
OEM
SENSOR
TYPE (CODE)
OEM
EVENT/READING
TYPE (CODE)
DESCRIPTION
Firmware Info 1 (C0h) 70h Internal Diagnostic Data
Firmware Info 2 (C0h) 71h Internal Diagnostic Data
Config Error (CEh) 6Fh
(sensor type specific)
Sensor-specific
Offset
Event
00h Configuration OK, no error.
01h Reserved
02h Unsupported Board
03h Unsupported Hardware
04h Reserved
05h Reserved
06h Reserved
07h Reserved
08h PCIe Configuration Conflict with
(active) uEFI setting
09h PCIe (uEFI FW bank 0) – conflict
0Ah PCIe (uEFI FW bank 1) – conflict
Board Reset (C4h) 6Fh
(sensor type specific)
Sensor-specific
Offset
Event
00h Reserved
01h HwPowerReset
02h PCIReset
03h HwWatchDogReset
04h SoftReset
05h Reserved
06h ColdReset
07h IPMICommand
08h Reserved
09h Reserved
0Ah BMCWatchdog
Vue de la page 31