www.kontron.com
6 Special Features
6.1 Watchdog Timer (WDT)
The watchdog timer is managed via the CPLD component, the Altera EPM1270 CPLD. The implementation complies
with the COM Express® specification. Timer modes 1, 2, and 3 are supported. For additional implementation
information, refer to the
PICMG COM Express® Module Base Specification.
6.2 General Purpose Input and Output (GPIO)
The COMe-cTH6 COM provides four interrupt-capable general purpose inputs and four general purpose outputs that
can be accessed through the COM Express connector as defined in the pin-out lists, in Section 4.1. The GPIO
controller is in the CPLD and the interface can be enabled in the BIOS setup.
Bit of GPIO Port0
Function
COM Express Pin
0
GPI0
A54
1
GPI1
A63
2
GPI2
A67
3
GPI3
A85
4
GPO0
A93
5
GPO1
B54
6
GPO2
B57
7
GPO3
B63
Table 11: COM Express GPIO Pin-Outs