Kontron AT8404 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Kontron AT8404. Kontron AT8404 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 132
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
www.kontron.com
If it's embedded, it's Kontron.
» Kontron User's Guide «
Document Revision 1.6
Document ID: AT8404
Issue Date: 16 March, 2010
AT8404
Vue de la page 0
1 2 3 4 5 6 ... 131 132

Résumé du contenu

Page 1 - » Kontron User's Guide «

www.kontron.comIf it's embedded, it's Kontron. » Kontron User's Guide «Document Revision 1.6Document ID: AT8404Issue Date: 16 March,

Page 2 - Customer Service

Prefacex AT8404 User Guidewww.kontron.comFor Your SafetyYour new Kontron product was developed and tested carefully to provide all features necessary

Page 3 - Table of Contents

Software Description87 AT8404 User Guidewww.kontron.com image2 : Product ID : 5307 Product Variant : 0 U-Boot

Page 4

Software Description88 AT8404 User Guidewww.kontron.com-------------------------------------------------------------------------------|ID | Name

Page 5 - List of Tables

Software Description89 AT8404 User Guidewww.kontron.comThe onboard FPGA can be updated using the 'copy' command from the Fastpath CLI:(Ethe

Page 6

Software Description90 AT8404 User Guidewww.kontron.com4.5 Carrier Clocking4.5.1 Clock source to AMCThe receive clocks of each AMC in the Carrier can

Page 7 - List of Figures

Software Description91 AT8404 User Guidewww.kontron.com• AMC B1 TCLKA is sourced by AMC B2 (TCLKB)Figure 4-2: AMC TCLKA sourced by AMC TCLKB• AMC B1

Page 8 - Trademarks

Software Description92 AT8404 User Guidewww.kontron.com4.5.2 Clock source to backplane from any AMCs TCLK-B/DThe Clock source selection is done by OE

Page 9 - Explanation of Symbols

Software Description93 AT8404 User Guidewww.kontron.com4.5.2.1 Clock ekeyingEndpoint for the clock match finder has to be set in indirect clock confi

Page 10 - For Your Safety

Software Description94 AT8404 User Guidewww.kontron.com3. Configure MUX (domain 1) for AMC B2(Ethernet Fabric) #set board clock mux-bpl clk3b amcb2 t

Page 11

Software Description95 AT8404 User Guidewww.kontron.com3. Check config(Ethernet Fabric) #show boardinfo clock amc AMC clock Source/Target Stat

Page 12 - General Instructions on Usage

Software Description96 AT8404 User Guidewww.kontron.comvlan pvid 4002vlan tagging 4003 exit

Page 13 - Two Year Warranty

Prefacexi AT8404 User Guidewww.kontron.comSpecial Handling and Unpacking InstructionsDo not handle this product out of its protective enclosure while

Page 14 - Introduction

Software Description97 AT8404 User Guidewww.kontron.com interface 0/9 description AMC_B2_FI_Port_11vlan part

Page 15 - 1. Introduction

Software Description98 AT8404 User Guidewww.kontron.cominterface 0/16 description AMC_B4_FI_Port_8vlan participation exclude 1vlan parti

Page 16 - 3 AT8404 User Guide

Software Description99 AT8404 User Guidewww.kontron.com interface 0/23 description BI_Channel_1 exit

Page 17 - 1.1.2 General compliances

Software Description100 AT8404 User Guidewww.kontron.com•kex_ipmi• Basic IPMI features: •Sensor list• SEL entries•FRU entries• FRU-Device information

Page 18 - 1.1.5 Board Options

Software Description101 AT8404 User Guidewww.kontron.com4.6.2.1 Configuring SNMP trapsSending SNMP traps from the AT8404 carrier can be configured ei

Page 19 - 1.2 Technical Specification

Software Description102 AT8404 User Guidewww.kontron.com4.6.3 Using the “current-settings” fileThe current-settings file is used to do the default co

Page 20 - 7 AT8404 User Guide

Software Description103 AT8404 User Guidewww.kontron.com#### Set to "no" to disable all network## interfaces.#### Configuration Settings fo

Page 21 - 8 AT8404 User Guide

Software Description104 AT8404 User Guidewww.kontron.comCONFIG_ETH1_IP="dhcp"CONFIG_ETH1_NETMASK=""CONFIG_ETH1_BROADCAST="&q

Page 22 - 1.3 Software Support

Software Description105 AT8404 User Guidewww.kontron.com4.6.3.1 Enabling Telnet access for port 2323 (linux)This setting allows to access the Carrier

Page 23 - 10 AT8404 User Guide

106KTC5520/EATXChapter 5Thermal Considerationswww.kontron.com

Page 24 - Installation

Prefacexii AT8404 User Guidewww.kontron.comGeneral Instructions on UsageIn order to maintain Kontron’s product warranty, this product must not be alt

Page 25 - 2. Installation

Thermal Considerations107 AT8404 User Guidewww.kontron.com5. Thermal ConsiderationsThe following chapters provide system integrators with the necessa

Page 26 - 13 AT8404 User Guide

Thermal Considerations108 AT8404 User Guidewww.kontron.comThe following table shows the temperature thresholds of all sensors.Temperature values are

Page 27 - 2.5 Software Installation

Thermal Considerations109 AT8404 User Guidewww.kontron.com5.3 AirflowIn order to allow system integrators to optimize environmental conditions for th

Page 28 - 2.6 Quick Start

Thermal Considerations110 AT8404 User Guidewww.kontron.comIn configuration B, all four AMC slots are populated with air blocker modules. The air bloc

Page 29 - 16 AT8404 User Guide

1KTC5520/EATXAppendix AGetting Helpwww.kontron.com

Page 30 - 2.6.3 Storage Configuration

Getting HelpA-2 AT8404 User Guidewww.kontron.comA. Getting HelpIf, at any time, you encounter difficulties with your application or with any of our p

Page 31 - Hardware Description

Getting HelpA-3 AT8404 User Guidewww.kontron.com•Fax• Send us a fax at: North America (450) 437-0304, EMEA +49 (0) 8341 803 339. In the fax, you must

Page 32 - 3. Hardware Description

1KTC5520/EATXAppendix BGlossarywww.kontron.com

Page 33 - 3.1.1 Ethernet Switch

GlossaryB-2 AT8404 User Guidewww.kontron.comB. GlossaryAcronyms DescriptionsACPI Advanced Configuration & Power InterfaceAdvancedMC (Same as AM

Page 34 - 21 AT8404 User Guide

GlossaryB-3 AT8404 User Guidewww.kontron.comDMI Desktop Management InterfaceDRAM Dynamic Random Access MemoryDTC Data Transfer ControllerDTR Data

Page 35 - 3.1.2.4 Flash ROM

Prefacexiii AT8404 User Guidewww.kontron.comTwo Year WarrantyKontron AG grants the original purchaser of Kontron’s products a TWO YEAR LIMITED HAR

Page 36 - 3.1.4 Storage Interconnect

GlossaryB-4 AT8404 User Guidewww.kontron.comIPMB-0 Intelligent Platform Management Bus Channel 0, the logical aggregation of IPMB-A and IPMB-B.IPMB-A

Page 37 - 3.1.6 AMC Bays

GlossaryB-5 AT8404 User Guidewww.kontron.comPHYPHYsical layer. Generic electronics term referring to a special electronic integrated circuit or funct

Page 38 - 25 AT8404 User Guide

GlossaryB-6 AT8404 User Guidewww.kontron.comUSB Universal Serial BusVLAN Virtual Local Area NetworkWD WatchDogWDT WatchDog TimerAcronyms Descript

Page 39 - 26 AT8404 User Guide

1KTC5520/EATXChapter 1Introductionwww.kontron.com

Page 40 - 27 AT8404 User Guide

Introduction2 AT8404 User Guidewww.kontron.com1. IntroductionThe Board described in this manual is designed for the Advanced Telecom Computing Archit

Page 41 - 3.1.7 IPMI

Introduction3 AT8404 User Guidewww.kontron.com• Supports 5 AMC GbE interfaces per AMC slot• Supports a 10/100/1000Base-T interfaces to the RTM• Suppo

Page 42 - 3.1.8 RTM Interface

Introduction4 AT8404 User Guidewww.kontron.com1.1.1.8 RTM Connector• Support for 7 RTM lanes from each AMC• FE and RS232 (RJ45) management ports• 2x

Page 43 - Table 3-13: J30 Assignment

Introduction5 AT8404 User Guidewww.kontron.com1.1.3 Optional Accessories1.1.3.1 AMCUp to four mid-size single width or up to two mid-size double widt

Page 44 - Table 3-14: J31 Assignment

Introduction6 AT8404 User Guidewww.kontron.com1.2 Technical SpecificationTable 1-2: AT8404 Main SpecificationsAT8404 SPECIFICATIONSUnit Computer and

Page 45 - 3.1.9 Power Supply

ii AT8404 User Guidewww.kontron.comRevision HistoryCustomer ServiceVisit our site at:www.kontron.com © 2010 Kontron, an International Corporation. All

Page 46 - 3.1.9.4 Power Supply AMCs

Introduction7 AT8404 User Guidewww.kontron.comInterfacesBackplane (Zone 2)•Base channels 1 and 2: 1 x GbE (1000BASE-T)•Fabric channels 1 and 2: 1 x 1

Page 47 - 3.1.10 Jumpers

Introduction8 AT8404 User Guidewww.kontron.comGeneralHumidityDesigned to meet or exceed the following: •Bellcore GR-63, Section 4.1•Operating: 15%-90

Page 48 - 35 AT8404 User Guide

Introduction9 AT8404 User Guidewww.kontron.com1.3 Software SupportThe following table contains information related to software supported by the AT840

Page 49 - 3.1.11 Front Panel Elements

Introduction10 AT8404 User Guidewww.kontron.com Supported MIBS• Switching Package MIBs• RFC 1213 - MIB-II• RFC 1493 - Bridge MIB• RFC 1643 - Ethernet

Page 50 - Table 3-19: Symbols Chart

11KTC5520/EATXChapter 2Installationwww.kontron.com

Page 51 - 3.2 RTM8030

Installation12 AT8404 User Guidewww.kontron.com2. InstallationThe AT8404 has been designed for easy installation. However, the following standard pre

Page 52 - 3.2.1 Hot Swap

Installation13 AT8404 User Guidewww.kontron.com2.2 AT8404 Initial Installation ProceduresThe following procedures are applicable only for the initial

Page 53 - 40 AT8404 User Guide

Installation14 AT8404 User Guidewww.kontron.com2.3 Standard Removal ProceduresTo remove the board proceed as follows:1. Ensure that the safety requir

Page 54 - 3.2.4 GbE Port

Installation15 AT8404 User Guidewww.kontron.com2.6 Quick StartThis section gives instructions for (initially) accessing the CLI (Command Line Interfa

Page 55 - 3.2.6 SAS Hard Drive Option

Installation16 AT8404 User Guidewww.kontron.com3. Wait for boot process to complete, i.e. until the console selection menu appears. b - connect Base

Page 56 - 3.2.7 Display Elements

iii AT8404 User Guidewww.kontron.comTable of ContentsRevision History ...

Page 57

Installation17 AT8404 User Guidewww.kontron.com2.6.3 Storage ConfigurationThe storage connection on Port 2 of AMC B4 is linked to AMC B2 (port 2) by

Page 58 - 4. Software Description

18KTC5520/EATXChapter 3Hardware Descriptionwww.kontron.com

Page 59 - 4.1.1.3 System Facilities

Hardware Description19 AT8404 User Guidewww.kontron.com3. Hardware DescriptionThis chapter describes the board specific items of the AdvancedTCA AMC

Page 60 - 4.1.2.1 DiffServ

Hardware Description20 AT8404 User Guidewww.kontron.comThe main building blocks of the base board are:• Ethernet Switch• Unit Computer and Memory• Fa

Page 61 - 4.1.3 Fastpath Management

Hardware Description21 AT8404 User Guidewww.kontron.com3.1.2 Unit Computer and MemoryA PowerPC PPC405GPr-400MHz 32 bit RISC processor with 16KB D-cac

Page 62 - 49 AT8404 User Guide

Hardware Description22 AT8404 User Guidewww.kontron.comThe front plate connector has the following pinning: The RS232 Management Interface uses the f

Page 63 - 4.2 Bootloader

Hardware Description23 AT8404 User Guidewww.kontron.com3.1.3 Fat Pipe InterconnectAMC bays B1 and B2 as well as B3 and B4 are directly (copper) inter

Page 64 - Table 4-2: POST Boot Steps

Hardware Description24 AT8404 User Guidewww.kontron.com3.1.5 Synchronous Clock DistributionAn FPGA is the global clock distribution device on the car

Page 65 - 52 AT8404 User Guide

Hardware Description25 AT8404 User Guidewww.kontron.com20 Extended RTM, AMC_B1_P20TCLKA Clock From BackplaneTCLKB Clock To BackplaneTCLKC Clock From

Page 66 - 53 AT8404 User Guide

Hardware Description26 AT8404 User Guidewww.kontron.comTable 3-10: AMC B3 Port Assignment Port Region Connection0 GbE GbE Switch 0/151 GbE -2 Storage

Page 67 - 4.3 IPMI Firmware

iv AT8404 User Guidewww.kontron.com3.2 RTM8030 ...

Page 68 - 0 AT8404

Hardware Description27 AT8404 User Guidewww.kontron.comTable 3-11: AMC B4 Port AssignmentPort Region Connection0 GbE GbE Switch 0/201 GbE -2 Storage

Page 69 - 56 AT8404 User Guide

Hardware Description28 AT8404 User Guidewww.kontron.comGigabit EthernetPort 0 and ports 8 to 11 of each AMC are connected to the Ethernet switch. The

Page 70 - 57 AT8404 User Guide

Hardware Description29 AT8404 User Guidewww.kontron.comThe internal Flash memory of the IPMC is divided into two distinct parts, the IPMI firmware an

Page 71 - 58 AT8404 User Guide

Hardware Description30 AT8404 User Guidewww.kontron.comThe Zone 3 connectors have the following pin assignments.Table 3-13: J30 Assignment J30 ROW A

Page 72 - 59 AT8404 User Guide

Hardware Description31 AT8404 User Guidewww.kontron.comTable 3-14: J31 Assignment J31ROW A AB ROW B ROW C CD ROW D1 N.C. GND N.C. N.C. GND N.C.2 N.C.

Page 73 - Internal IPMC firmware

Hardware Description32 AT8404 User Guidewww.kontron.comSignals with TX in their name are driven by the front board, those with RX are driven by the R

Page 74 - 61 AT8404 User Guide

Hardware Description33 AT8404 User Guidewww.kontron.com3.1.9.1 Power ConnectorThe power connector supplies the board with two 48V redundant rails, di

Page 75 - Event trigger

Hardware Description34 AT8404 User Guidewww.kontron.com3.1.9.5 Power Supply RTMThe RTM has its own power supply. The 12V payload power is generated b

Page 76

Hardware Description35 AT8404 User Guidewww.kontron.comTable 3-18: Jumper Settings ( • Default Setting)F_SPI_PROG FPGA Configuration Programming in•

Page 77

Hardware Description36 AT8404 User Guidewww.kontron.com3.1.11 Front Panel ElementsFigure 3-2: Front Panel of AT8404The four front panel ATCA LEDs dis

Page 78

v AT8404 User Guidewww.kontron.comList of TablesTable 1-1: AMC Slot Options ...

Page 79 - Event trigger

Hardware Description37 AT8404 User Guidewww.kontron.comTable 3-19: Symbols ChartLED Signification LEDActivity ATCA LED3 (amber/green)Healthy ATCA LED

Page 80 - 67 AT8404 User Guide

Hardware Description38 AT8404 User Guidewww.kontron.com3.2 RTM8030The RTM8030 is a single slot (6HP) ATCA Rear Transition Module. This RTM provides a

Page 81 - 4.3.2 OEM Commands

Hardware Description39 AT8404 User Guidewww.kontron.com3.2.1 Hot SwapThe RTM8030 supports hot swapping by using the switch connected to the face plat

Page 82 - 4.3.2.3 OemApSetFirmCap

Hardware Description40 AT8404 User Guidewww.kontron.comConnection to the RJ45 can be established with a straight through Ethernet cable and a RJ45 (f

Page 83 - 4.3.2.4 CmdClockSetBplDriver

Hardware Description41 AT8404 User Guidewww.kontron.com3.2.4 GbE PortThe SFP port is connected to the front board's GbE switch. The correspondin

Page 84 - 4.3.2.5 CmdClockGetBplDriver

Hardware Description42 AT8404 User Guidewww.kontron.com3.2.5 SAS ChannelsAn external x4 SAS/SATA connector provides access to two of the AT8404 AMC b

Page 85 - 4.3.2.6 CmdClockSetPLLConfig

Hardware Description43 AT8404 User Guidewww.kontron.com3.2.7 Display ElementsFigure 3-4: Front Panel of the RTM8030FESFP Gigabit Ethernet4x External

Page 86 - 4.3.2.7 CmdClockGetPLLConfig

44KTC5520/EATXChapter 4Software Descriptionwww.kontron.com

Page 87 - 4.3.2.8 CmdClockGetPLLStatus

Software Description45 AT8404 User Guidewww.kontron.com4. Software DescriptionSoftware on the AT8404 includes the following parts:• Bootloader• OS (r

Page 88 - 4.3.2.9 ClockSetClkMux

Software Description46 AT8404 User Guidewww.kontron.com• GMRP – Dynamic L2 multicast registration: clause 10, 802.1D-2004• GVRP – Dynamic VLAN regist

Page 89 - 76 AT8404 User Guide

vi AT8404 User Guidewww.kontron.comTable 4-11: Kontron FRU over current sensor ...

Page 90 - 4.3.2.10 ClockGetClkMux

Software Description47 AT8404 User Guidewww.kontron.com• RFC 2868 – RADIUS attributes for tunnel protocol support • RFC 2869 – RADIUS extensions• rfc

Page 91 - 78 AT8404 User Guide

Software Description48 AT8404 User Guidewww.kontron.com• Permit/deny actions for inbound or outbound Layer 2 traffic classification based on:• Source

Page 92 - 79 AT8404 User Guide

Software Description49 AT8404 User Guidewww.kontron.com• RFC 2295 – Transparent content negotiation• RFC 2296 – Remote variant selection; RSVA/1.0 st

Page 93 - 4.3.2.15 CmdSetPcieClkSrc

Software Description50 AT8404 User Guidewww.kontron.com4.2 Bootloader On the AT8404 Carrier board, the bootloader ‘u-boot‘ (universal bootloader) is

Page 94 - 4.3.2.16 SetClockState

Software Description51 AT8404 User Guidewww.kontron.comTable 4-2: POST Boot Steps POST Step Code Value Boot StepPC_INIT 0x00 Initial PC, EBC has been

Page 95 - 4.3.4 E-Keying

Software Description52 AT8404 User Guidewww.kontron.com4.2.2 Bootloader shell optionsThe boot process can be interrupted by entering the bootstopkey

Page 96 - 4.3.6 LEDs

Software Description53 AT8404 User Guidewww.kontron.comwatchdogboot0 – disable boot monitor watchdog (default)5...n – timeout in seconds before boot

Page 97 - 4.3.7 Hot Swap Process

Software Description54 AT8404 User Guidewww.kontron.com4.3 IPMI FirmwareThe Unit Computer communicates with the Intelligent Platform Management Contr

Page 98 - 4.4 Firmware Administration

Software Description55 AT8404 User Guidewww.kontron.comTable 4-4: AT8404 sensorsSDR IDNameSensor Type CodeReading Type CodeDescription Event Offset0

Page 99 - 4.4.1 Updating the Firmware

Software Description56 AT8404 User Guidewww.kontron.com9PPC POST Error0x0F(System Firm-ware Progress)0x6F(Sensor Spe-cific)Generates an event when a

Page 100 - 4.4.2 Updating IPMI FW

vii AT8404 User Guidewww.kontron.comList of FiguresFigure 3-1: Functional Block Diagram Base Board...

Page 101 - 4.4.3 Updating PLD

Software Description57 AT8404 User Guidewww.kontron.com18FRU2 Hot Swap0xF0(PICMG Hot Swap)0x6F(Sensor Spe-cific)PICMG hotswap sensor for AMC B2see PI

Page 102 - Note

Software Description58 AT8404 User Guidewww.kontron.com33FRU4 FRU Agent0xC5(FRU Info Agent)0x6F(Sensor Spe-cific)Generates an event when the FRU data

Page 103 - 4.5 Carrier Clocking

Software Description59 AT8404 User Guidewww.kontron.com39FRU4 Pwr Denied0xCD(FRU Power denied)0x03(Digital Dis-crete)Generates an event when power fo

Page 104 - 91 AT8404 User Guide

Software Description60 AT8404 User Guidewww.kontron.com53Vcc 2.5v FRU00x02(Voltage)0x01(Threshold)Voltage on 2.5v board power supplyFor sensor thresh

Page 105 - 92 AT8404 User Guide

Software Description61 AT8404 User Guidewww.kontron.com66 IPMC FwUp0xCA(External Com-ponent Firm-ware Upgrade Status)0x6F(Sensor Spe-cific)Generates

Page 106 - 4.5.3 Examples

Software Description62 AT8404 User Guidewww.kontron.com4.3.1.1 OEM sensor descriptionKontron FRU Info AgentTable 4-5: Kontron FRU info agent sensorEv

Page 107 - 4.5.3.2 Example 2

Software Description63 AT8404 User Guidewww.kontron.comKontron IPMB-L LinkTable 4-6: Kontron IPMB-L Link sensorEvent/Reading type codeSensor typeSens

Page 108 - 4.6 Carrier Configuration

Software Description64 AT8404 User Guidewww.kontron.comKontron POST Code ValueKontron Switch Management StatusKontron Diagnostic StatusKontron Extern

Page 109 - 96 AT8404 User Guide

Software Description65 AT8404 User Guidewww.kontron.comKontron FRU Over CurrentKontron FRU Power DeniedKontron ResetTable 4-11: Kontron FRU over curr

Page 110 - 97 AT8404 User Guide

Software Description66 AT8404 User Guidewww.kontron.comKontron Clock Input StatusKontron PLL Status4.3.1.2 Sensor ThresholdsFollowing tables show sen

Page 111 - 98 AT8404 User Guide

Prefaceviii AT8404 User Guidewww.kontron.comProprietary NoteThis document contains information proprietary to Kontron AG. It may not be copied or tra

Page 112 - 4.6.2 Using SNMP

Software Description67 AT8404 User Guidewww.kontron.comTable 4-17: Voltage Sensor Thresholds SENSOR Number / ID stringLower Non-Recoverabl

Page 113 - 100 AT8404 User Guide

Software Description68 AT8404 User Guidewww.kontron.com4.3.2 OEM CommandsThe AT8404 supports the following OEM commands. 4.3.2.1 OemApGetReleaseInfoT

Page 114 - 101 AT8404 User Guide

Software Description69 AT8404 User Guidewww.kontron.com4.3.2.2 OemApGetFirmCap4.3.2.3 OemApSetFirmCapCommand Name NetFn LUN Command NumberOemApGetFir

Page 115 - 102 AT8404 User Guide

Software Description70 AT8404 User Guidewww.kontron.com4.3.2.4 CmdClockSetBplDriverThis command controls the LVDS driver device on the backplane for

Page 116 - 103 AT8404 User Guide

Software Description71 AT8404 User Guidewww.kontron.com4.3.2.5 CmdClockGetBplDriverThis command provides information about the LVDS driver device on

Page 117 - 104 AT8404 User Guide

Software Description72 AT8404 User Guidewww.kontron.com4.3.2.6 CmdClockSetPLLConfigCommand Name NetFn LUN Command NumberCmdClockSetPLLConfig 0x30 3 0

Page 118 - 105 AT8404 User Guide

Software Description73 AT8404 User Guidewww.kontron.com4.3.2.7 CmdClockGetPLLConfigCommand Name NetFn LUN Command NumberCmdClockGetPLLConfig 0x30 3 0

Page 119 - Thermal Considerations

Software Description74 AT8404 User Guidewww.kontron.com4.3.2.8 CmdClockGetPLLStatusCommand Name NetFn LUN Command NumberCmdClockGetPLLStatus 0x30 3 0

Page 120 - 5. Thermal Considerations

Software Description75 AT8404 User Guidewww.kontron.com4.3.2.9 ClockSetClkMuxWith this command the clock MUX 0 and MUX 1 can be configured to select

Page 121 - 5.2 Thermal Regulation

Software Description76 AT8404 User Guidewww.kontron.comByte Num Data FieldRequest Data 1...5Token: 0xAB - (~T) 0xCA - (~5) 0xCC - (~3) 0xCF - (~0

Page 122 - 5.3 Airflow

Prefaceix AT8404 User Guidewww.kontron.comExplanation of Symbols CAUTION This symbol and title indicate potential damage to hardware and tellsyou how

Page 123 - 110 AT8404 User Guide

Software Description77 AT8404 User Guidewww.kontron.com4.3.2.10 ClockGetClkMuxSee CmdClockSetClkMux() command.Command Name NetFn LUN Command NumberCl

Page 124 - Getting Help

Software Description78 AT8404 User Guidewww.kontron.com4.3.2.11 ClockSetAmcClkBufferOverrrideControls the LVDS driver device on the backplane for the

Page 125 - A. Getting Help

Software Description79 AT8404 User Guidewww.kontron.com4.3.2.12 CmdGetStoragePortSelectionThis command reads the current setting of the storage switc

Page 126 - A.2 When Returning a Unit

Software Description80 AT8404 User Guidewww.kontron.com4.3.2.14 CmdGetPcieClkSrcThis command returns the selected character of the PCIe clock source.

Page 127 - Glossary

Software Description81 AT8404 User Guidewww.kontron.com4.3.2.16 SetClockState See PICMG AMC.0 R2.0 table 3-44.Ipmitool clk set <CLK-ID> <ind

Page 128 - B. Glossary

Software Description82 AT8404 User Guidewww.kontron.com4.3.2.17 GetClockState See PICMG AMC.0 R2.0 table 3-45.4.3.3 Field Replaceable Unit (FRU) Info

Page 129 - B-3 AT8404 User Guide

Software Description83 AT8404 User Guidewww.kontron.com4.3.5 IPMC Firmware CodeIPMC firmware code is organized into boot code and operational code, b

Page 130 - B-4 AT8404 User Guide

Software Description84 AT8404 User Guidewww.kontron.com4.3.6.3 Health LED (ATCA LED2)Green/Amber LED4.3.6.4 Customer Definable LED (ATCA LED 3)This i

Page 131 - B-5 AT8404 User Guide

Software Description85 AT8404 User Guidewww.kontron.com4.4 Firmware AdministrationOn a running AT8404 system, the switching application is executed f

Page 132 - Acronyms Descriptions

Software Description86 AT8404 User Guidewww.kontron.com4.4.1 Updating the FirmwareThe update package comes as a group of packages, located in the \re

Commentaires sur ces manuels

Pas de commentaire