www.kontron.comIf it's embedded, it's Kontron. » Kontron User's Guide «Document Revision 1.6Document ID: AT8404Issue Date: 16 March,
Prefacex AT8404 User Guidewww.kontron.comFor Your SafetyYour new Kontron product was developed and tested carefully to provide all features necessary
Software Description87 AT8404 User Guidewww.kontron.com image2 : Product ID : 5307 Product Variant : 0 U-Boot
Software Description88 AT8404 User Guidewww.kontron.com-------------------------------------------------------------------------------|ID | Name
Software Description89 AT8404 User Guidewww.kontron.comThe onboard FPGA can be updated using the 'copy' command from the Fastpath CLI:(Ethe
Software Description90 AT8404 User Guidewww.kontron.com4.5 Carrier Clocking4.5.1 Clock source to AMCThe receive clocks of each AMC in the Carrier can
Software Description91 AT8404 User Guidewww.kontron.com• AMC B1 TCLKA is sourced by AMC B2 (TCLKB)Figure 4-2: AMC TCLKA sourced by AMC TCLKB• AMC B1
Software Description92 AT8404 User Guidewww.kontron.com4.5.2 Clock source to backplane from any AMCs TCLK-B/DThe Clock source selection is done by OE
Software Description93 AT8404 User Guidewww.kontron.com4.5.2.1 Clock ekeyingEndpoint for the clock match finder has to be set in indirect clock confi
Software Description94 AT8404 User Guidewww.kontron.com3. Configure MUX (domain 1) for AMC B2(Ethernet Fabric) #set board clock mux-bpl clk3b amcb2 t
Software Description95 AT8404 User Guidewww.kontron.com3. Check config(Ethernet Fabric) #show boardinfo clock amc AMC clock Source/Target Stat
Software Description96 AT8404 User Guidewww.kontron.comvlan pvid 4002vlan tagging 4003 exit
Prefacexi AT8404 User Guidewww.kontron.comSpecial Handling and Unpacking InstructionsDo not handle this product out of its protective enclosure while
Software Description97 AT8404 User Guidewww.kontron.com interface 0/9 description AMC_B2_FI_Port_11vlan part
Software Description98 AT8404 User Guidewww.kontron.cominterface 0/16 description AMC_B4_FI_Port_8vlan participation exclude 1vlan parti
Software Description99 AT8404 User Guidewww.kontron.com interface 0/23 description BI_Channel_1 exit
Software Description100 AT8404 User Guidewww.kontron.com•kex_ipmi• Basic IPMI features: •Sensor list• SEL entries•FRU entries• FRU-Device information
Software Description101 AT8404 User Guidewww.kontron.com4.6.2.1 Configuring SNMP trapsSending SNMP traps from the AT8404 carrier can be configured ei
Software Description102 AT8404 User Guidewww.kontron.com4.6.3 Using the “current-settings” fileThe current-settings file is used to do the default co
Software Description103 AT8404 User Guidewww.kontron.com#### Set to "no" to disable all network## interfaces.#### Configuration Settings fo
Software Description104 AT8404 User Guidewww.kontron.comCONFIG_ETH1_IP="dhcp"CONFIG_ETH1_NETMASK=""CONFIG_ETH1_BROADCAST="&q
Software Description105 AT8404 User Guidewww.kontron.com4.6.3.1 Enabling Telnet access for port 2323 (linux)This setting allows to access the Carrier
106KTC5520/EATXChapter 5Thermal Considerationswww.kontron.com
Prefacexii AT8404 User Guidewww.kontron.comGeneral Instructions on UsageIn order to maintain Kontron’s product warranty, this product must not be alt
Thermal Considerations107 AT8404 User Guidewww.kontron.com5. Thermal ConsiderationsThe following chapters provide system integrators with the necessa
Thermal Considerations108 AT8404 User Guidewww.kontron.comThe following table shows the temperature thresholds of all sensors.Temperature values are
Thermal Considerations109 AT8404 User Guidewww.kontron.com5.3 AirflowIn order to allow system integrators to optimize environmental conditions for th
Thermal Considerations110 AT8404 User Guidewww.kontron.comIn configuration B, all four AMC slots are populated with air blocker modules. The air bloc
1KTC5520/EATXAppendix AGetting Helpwww.kontron.com
Getting HelpA-2 AT8404 User Guidewww.kontron.comA. Getting HelpIf, at any time, you encounter difficulties with your application or with any of our p
Getting HelpA-3 AT8404 User Guidewww.kontron.com•Fax• Send us a fax at: North America (450) 437-0304, EMEA +49 (0) 8341 803 339. In the fax, you must
1KTC5520/EATXAppendix BGlossarywww.kontron.com
GlossaryB-2 AT8404 User Guidewww.kontron.comB. GlossaryAcronyms DescriptionsACPI Advanced Configuration & Power InterfaceAdvancedMC (Same as AM
GlossaryB-3 AT8404 User Guidewww.kontron.comDMI Desktop Management InterfaceDRAM Dynamic Random Access MemoryDTC Data Transfer ControllerDTR Data
Prefacexiii AT8404 User Guidewww.kontron.comTwo Year WarrantyKontron AG grants the original purchaser of Kontron’s products a TWO YEAR LIMITED HAR
GlossaryB-4 AT8404 User Guidewww.kontron.comIPMB-0 Intelligent Platform Management Bus Channel 0, the logical aggregation of IPMB-A and IPMB-B.IPMB-A
GlossaryB-5 AT8404 User Guidewww.kontron.comPHYPHYsical layer. Generic electronics term referring to a special electronic integrated circuit or funct
GlossaryB-6 AT8404 User Guidewww.kontron.comUSB Universal Serial BusVLAN Virtual Local Area NetworkWD WatchDogWDT WatchDog TimerAcronyms Descript
1KTC5520/EATXChapter 1Introductionwww.kontron.com
Introduction2 AT8404 User Guidewww.kontron.com1. IntroductionThe Board described in this manual is designed for the Advanced Telecom Computing Archit
Introduction3 AT8404 User Guidewww.kontron.com• Supports 5 AMC GbE interfaces per AMC slot• Supports a 10/100/1000Base-T interfaces to the RTM• Suppo
Introduction4 AT8404 User Guidewww.kontron.com1.1.1.8 RTM Connector• Support for 7 RTM lanes from each AMC• FE and RS232 (RJ45) management ports• 2x
Introduction5 AT8404 User Guidewww.kontron.com1.1.3 Optional Accessories1.1.3.1 AMCUp to four mid-size single width or up to two mid-size double widt
Introduction6 AT8404 User Guidewww.kontron.com1.2 Technical SpecificationTable 1-2: AT8404 Main SpecificationsAT8404 SPECIFICATIONSUnit Computer and
ii AT8404 User Guidewww.kontron.comRevision HistoryCustomer ServiceVisit our site at:www.kontron.com © 2010 Kontron, an International Corporation. All
Introduction7 AT8404 User Guidewww.kontron.comInterfacesBackplane (Zone 2)•Base channels 1 and 2: 1 x GbE (1000BASE-T)•Fabric channels 1 and 2: 1 x 1
Introduction8 AT8404 User Guidewww.kontron.comGeneralHumidityDesigned to meet or exceed the following: •Bellcore GR-63, Section 4.1•Operating: 15%-90
Introduction9 AT8404 User Guidewww.kontron.com1.3 Software SupportThe following table contains information related to software supported by the AT840
Introduction10 AT8404 User Guidewww.kontron.com Supported MIBS• Switching Package MIBs• RFC 1213 - MIB-II• RFC 1493 - Bridge MIB• RFC 1643 - Ethernet
11KTC5520/EATXChapter 2Installationwww.kontron.com
Installation12 AT8404 User Guidewww.kontron.com2. InstallationThe AT8404 has been designed for easy installation. However, the following standard pre
Installation13 AT8404 User Guidewww.kontron.com2.2 AT8404 Initial Installation ProceduresThe following procedures are applicable only for the initial
Installation14 AT8404 User Guidewww.kontron.com2.3 Standard Removal ProceduresTo remove the board proceed as follows:1. Ensure that the safety requir
Installation15 AT8404 User Guidewww.kontron.com2.6 Quick StartThis section gives instructions for (initially) accessing the CLI (Command Line Interfa
Installation16 AT8404 User Guidewww.kontron.com3. Wait for boot process to complete, i.e. until the console selection menu appears. b - connect Base
iii AT8404 User Guidewww.kontron.comTable of ContentsRevision History ...
Installation17 AT8404 User Guidewww.kontron.com2.6.3 Storage ConfigurationThe storage connection on Port 2 of AMC B4 is linked to AMC B2 (port 2) by
18KTC5520/EATXChapter 3Hardware Descriptionwww.kontron.com
Hardware Description19 AT8404 User Guidewww.kontron.com3. Hardware DescriptionThis chapter describes the board specific items of the AdvancedTCA AMC
Hardware Description20 AT8404 User Guidewww.kontron.comThe main building blocks of the base board are:• Ethernet Switch• Unit Computer and Memory• Fa
Hardware Description21 AT8404 User Guidewww.kontron.com3.1.2 Unit Computer and MemoryA PowerPC PPC405GPr-400MHz 32 bit RISC processor with 16KB D-cac
Hardware Description22 AT8404 User Guidewww.kontron.comThe front plate connector has the following pinning: The RS232 Management Interface uses the f
Hardware Description23 AT8404 User Guidewww.kontron.com3.1.3 Fat Pipe InterconnectAMC bays B1 and B2 as well as B3 and B4 are directly (copper) inter
Hardware Description24 AT8404 User Guidewww.kontron.com3.1.5 Synchronous Clock DistributionAn FPGA is the global clock distribution device on the car
Hardware Description25 AT8404 User Guidewww.kontron.com20 Extended RTM, AMC_B1_P20TCLKA Clock From BackplaneTCLKB Clock To BackplaneTCLKC Clock From
Hardware Description26 AT8404 User Guidewww.kontron.comTable 3-10: AMC B3 Port Assignment Port Region Connection0 GbE GbE Switch 0/151 GbE -2 Storage
iv AT8404 User Guidewww.kontron.com3.2 RTM8030 ...
Hardware Description27 AT8404 User Guidewww.kontron.comTable 3-11: AMC B4 Port AssignmentPort Region Connection0 GbE GbE Switch 0/201 GbE -2 Storage
Hardware Description28 AT8404 User Guidewww.kontron.comGigabit EthernetPort 0 and ports 8 to 11 of each AMC are connected to the Ethernet switch. The
Hardware Description29 AT8404 User Guidewww.kontron.comThe internal Flash memory of the IPMC is divided into two distinct parts, the IPMI firmware an
Hardware Description30 AT8404 User Guidewww.kontron.comThe Zone 3 connectors have the following pin assignments.Table 3-13: J30 Assignment J30 ROW A
Hardware Description31 AT8404 User Guidewww.kontron.comTable 3-14: J31 Assignment J31ROW A AB ROW B ROW C CD ROW D1 N.C. GND N.C. N.C. GND N.C.2 N.C.
Hardware Description32 AT8404 User Guidewww.kontron.comSignals with TX in their name are driven by the front board, those with RX are driven by the R
Hardware Description33 AT8404 User Guidewww.kontron.com3.1.9.1 Power ConnectorThe power connector supplies the board with two 48V redundant rails, di
Hardware Description34 AT8404 User Guidewww.kontron.com3.1.9.5 Power Supply RTMThe RTM has its own power supply. The 12V payload power is generated b
Hardware Description35 AT8404 User Guidewww.kontron.comTable 3-18: Jumper Settings ( • Default Setting)F_SPI_PROG FPGA Configuration Programming in•
Hardware Description36 AT8404 User Guidewww.kontron.com3.1.11 Front Panel ElementsFigure 3-2: Front Panel of AT8404The four front panel ATCA LEDs dis
v AT8404 User Guidewww.kontron.comList of TablesTable 1-1: AMC Slot Options ...
Hardware Description37 AT8404 User Guidewww.kontron.comTable 3-19: Symbols ChartLED Signification LEDActivity ATCA LED3 (amber/green)Healthy ATCA LED
Hardware Description38 AT8404 User Guidewww.kontron.com3.2 RTM8030The RTM8030 is a single slot (6HP) ATCA Rear Transition Module. This RTM provides a
Hardware Description39 AT8404 User Guidewww.kontron.com3.2.1 Hot SwapThe RTM8030 supports hot swapping by using the switch connected to the face plat
Hardware Description40 AT8404 User Guidewww.kontron.comConnection to the RJ45 can be established with a straight through Ethernet cable and a RJ45 (f
Hardware Description41 AT8404 User Guidewww.kontron.com3.2.4 GbE PortThe SFP port is connected to the front board's GbE switch. The correspondin
Hardware Description42 AT8404 User Guidewww.kontron.com3.2.5 SAS ChannelsAn external x4 SAS/SATA connector provides access to two of the AT8404 AMC b
Hardware Description43 AT8404 User Guidewww.kontron.com3.2.7 Display ElementsFigure 3-4: Front Panel of the RTM8030FESFP Gigabit Ethernet4x External
44KTC5520/EATXChapter 4Software Descriptionwww.kontron.com
Software Description45 AT8404 User Guidewww.kontron.com4. Software DescriptionSoftware on the AT8404 includes the following parts:• Bootloader• OS (r
Software Description46 AT8404 User Guidewww.kontron.com• GMRP – Dynamic L2 multicast registration: clause 10, 802.1D-2004• GVRP – Dynamic VLAN regist
vi AT8404 User Guidewww.kontron.comTable 4-11: Kontron FRU over current sensor ...
Software Description47 AT8404 User Guidewww.kontron.com• RFC 2868 – RADIUS attributes for tunnel protocol support • RFC 2869 – RADIUS extensions• rfc
Software Description48 AT8404 User Guidewww.kontron.com• Permit/deny actions for inbound or outbound Layer 2 traffic classification based on:• Source
Software Description49 AT8404 User Guidewww.kontron.com• RFC 2295 – Transparent content negotiation• RFC 2296 – Remote variant selection; RSVA/1.0 st
Software Description50 AT8404 User Guidewww.kontron.com4.2 Bootloader On the AT8404 Carrier board, the bootloader ‘u-boot‘ (universal bootloader) is
Software Description51 AT8404 User Guidewww.kontron.comTable 4-2: POST Boot Steps POST Step Code Value Boot StepPC_INIT 0x00 Initial PC, EBC has been
Software Description52 AT8404 User Guidewww.kontron.com4.2.2 Bootloader shell optionsThe boot process can be interrupted by entering the bootstopkey
Software Description53 AT8404 User Guidewww.kontron.comwatchdogboot0 – disable boot monitor watchdog (default)5...n – timeout in seconds before boot
Software Description54 AT8404 User Guidewww.kontron.com4.3 IPMI FirmwareThe Unit Computer communicates with the Intelligent Platform Management Contr
Software Description55 AT8404 User Guidewww.kontron.comTable 4-4: AT8404 sensorsSDR IDNameSensor Type CodeReading Type CodeDescription Event Offset0
Software Description56 AT8404 User Guidewww.kontron.com9PPC POST Error0x0F(System Firm-ware Progress)0x6F(Sensor Spe-cific)Generates an event when a
vii AT8404 User Guidewww.kontron.comList of FiguresFigure 3-1: Functional Block Diagram Base Board...
Software Description57 AT8404 User Guidewww.kontron.com18FRU2 Hot Swap0xF0(PICMG Hot Swap)0x6F(Sensor Spe-cific)PICMG hotswap sensor for AMC B2see PI
Software Description58 AT8404 User Guidewww.kontron.com33FRU4 FRU Agent0xC5(FRU Info Agent)0x6F(Sensor Spe-cific)Generates an event when the FRU data
Software Description59 AT8404 User Guidewww.kontron.com39FRU4 Pwr Denied0xCD(FRU Power denied)0x03(Digital Dis-crete)Generates an event when power fo
Software Description60 AT8404 User Guidewww.kontron.com53Vcc 2.5v FRU00x02(Voltage)0x01(Threshold)Voltage on 2.5v board power supplyFor sensor thresh
Software Description61 AT8404 User Guidewww.kontron.com66 IPMC FwUp0xCA(External Com-ponent Firm-ware Upgrade Status)0x6F(Sensor Spe-cific)Generates
Software Description62 AT8404 User Guidewww.kontron.com4.3.1.1 OEM sensor descriptionKontron FRU Info AgentTable 4-5: Kontron FRU info agent sensorEv
Software Description63 AT8404 User Guidewww.kontron.comKontron IPMB-L LinkTable 4-6: Kontron IPMB-L Link sensorEvent/Reading type codeSensor typeSens
Software Description64 AT8404 User Guidewww.kontron.comKontron POST Code ValueKontron Switch Management StatusKontron Diagnostic StatusKontron Extern
Software Description65 AT8404 User Guidewww.kontron.comKontron FRU Over CurrentKontron FRU Power DeniedKontron ResetTable 4-11: Kontron FRU over curr
Software Description66 AT8404 User Guidewww.kontron.comKontron Clock Input StatusKontron PLL Status4.3.1.2 Sensor ThresholdsFollowing tables show sen
Prefaceviii AT8404 User Guidewww.kontron.comProprietary NoteThis document contains information proprietary to Kontron AG. It may not be copied or tra
Software Description67 AT8404 User Guidewww.kontron.comTable 4-17: Voltage Sensor Thresholds SENSOR Number / ID stringLower Non-Recoverabl
Software Description68 AT8404 User Guidewww.kontron.com4.3.2 OEM CommandsThe AT8404 supports the following OEM commands. 4.3.2.1 OemApGetReleaseInfoT
Software Description69 AT8404 User Guidewww.kontron.com4.3.2.2 OemApGetFirmCap4.3.2.3 OemApSetFirmCapCommand Name NetFn LUN Command NumberOemApGetFir
Software Description70 AT8404 User Guidewww.kontron.com4.3.2.4 CmdClockSetBplDriverThis command controls the LVDS driver device on the backplane for
Software Description71 AT8404 User Guidewww.kontron.com4.3.2.5 CmdClockGetBplDriverThis command provides information about the LVDS driver device on
Software Description72 AT8404 User Guidewww.kontron.com4.3.2.6 CmdClockSetPLLConfigCommand Name NetFn LUN Command NumberCmdClockSetPLLConfig 0x30 3 0
Software Description73 AT8404 User Guidewww.kontron.com4.3.2.7 CmdClockGetPLLConfigCommand Name NetFn LUN Command NumberCmdClockGetPLLConfig 0x30 3 0
Software Description74 AT8404 User Guidewww.kontron.com4.3.2.8 CmdClockGetPLLStatusCommand Name NetFn LUN Command NumberCmdClockGetPLLStatus 0x30 3 0
Software Description75 AT8404 User Guidewww.kontron.com4.3.2.9 ClockSetClkMuxWith this command the clock MUX 0 and MUX 1 can be configured to select
Software Description76 AT8404 User Guidewww.kontron.comByte Num Data FieldRequest Data 1...5Token: 0xAB - (~T) 0xCA - (~5) 0xCC - (~3) 0xCF - (~0
Prefaceix AT8404 User Guidewww.kontron.comExplanation of Symbols CAUTION This symbol and title indicate potential damage to hardware and tellsyou how
Software Description77 AT8404 User Guidewww.kontron.com4.3.2.10 ClockGetClkMuxSee CmdClockSetClkMux() command.Command Name NetFn LUN Command NumberCl
Software Description78 AT8404 User Guidewww.kontron.com4.3.2.11 ClockSetAmcClkBufferOverrrideControls the LVDS driver device on the backplane for the
Software Description79 AT8404 User Guidewww.kontron.com4.3.2.12 CmdGetStoragePortSelectionThis command reads the current setting of the storage switc
Software Description80 AT8404 User Guidewww.kontron.com4.3.2.14 CmdGetPcieClkSrcThis command returns the selected character of the PCIe clock source.
Software Description81 AT8404 User Guidewww.kontron.com4.3.2.16 SetClockState See PICMG AMC.0 R2.0 table 3-44.Ipmitool clk set <CLK-ID> <ind
Software Description82 AT8404 User Guidewww.kontron.com4.3.2.17 GetClockState See PICMG AMC.0 R2.0 table 3-45.4.3.3 Field Replaceable Unit (FRU) Info
Software Description83 AT8404 User Guidewww.kontron.com4.3.5 IPMC Firmware CodeIPMC firmware code is organized into boot code and operational code, b
Software Description84 AT8404 User Guidewww.kontron.com4.3.6.3 Health LED (ATCA LED2)Green/Amber LED4.3.6.4 Customer Definable LED (ATCA LED 3)This i
Software Description85 AT8404 User Guidewww.kontron.com4.4 Firmware AdministrationOn a running AT8404 system, the switching application is executed f
Software Description86 AT8404 User Guidewww.kontron.com4.4.1 Updating the FirmwareThe update package comes as a group of packages, located in the \re